floor towards attic (uninhabitable) solid wood construction, without lining, wooden surface
Fire performance | REI | 60 |
---|---|---|
maximum span = 5 m; maximum load Ed,fi = 0,6 kN/m²
Classified by HFA
Fire performance Germany
Classification: REI60
Load Ed,fi according to the German certification document
Proof: manufacturer-specific
|
||
Thermal performance | U | 0,11 W/(m2K) |
Diffusion | adequate | |
Calculated by TUM
|
||
Acoustic performance | Rw (C;Ctr) | 44 dB (-2; -7) |
Ln,w (Cl) | ||
Rating by Müller-BBM
|
||
Mass per unit area | m | 106,0 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 300,0 | mineral wool [040; 130] | 0,040 | 1 | 130 | 1,030 | |
B | membrane (airtight) | ||||||
C | 140,0 | cross laminated timber | 0,130 | 50 | 500 | 1,600 | D |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 96,473 | -102,346 | -5,873 | 66,064 | 957,600 | 1023,664 | 1302,831 | 28,512 | 1331,343 | 0,606 | 0,181 | 5.1733669E-6 | 0,248 |
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP [kgCO2Äqv.] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
A1 - A3 | -41,985 | 0,398 | 0,058 | 4.88E-6 | 0,033 | 318,506 | 1117,721 | 1433,547 | 893,863 | 74,533 | 967,649 |
C1 - C4 | 110,245 | 0,006 | 0,012 | 1.72E-7 | 0,001 | 1,168 | -1110,860 | -1109,692 | 24,256 | 0,000 | 24,256 |
A1 - C4 | 71,591 | 0,405 | 0,070 | 5.06E-6 | 0,035 | 319,686 | 6,861 | 323,867 | 919,850 | 74,533 | 993,636 |
Last update 02.08.2023/hfa.eco2soft