Skip to main content
Regional validity

Scope

solid wood construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 65,0 m' approx. 37 kg/m²
B 60,0 non-bonded chippings, m' approx. 93 kg/m² 0,700 1 1550 1,000 A1
C trickling protection E
D 160,0 cross laminated timber, first layer minimum 40mm 0,130 50 500 1,600 D
E 70,0 acoustic direct hanger with CD-profile (a=400)
F mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
G 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
G 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Ln,w(Cl) [dB] Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
gdmtxa04a-00 F 50,0 mineral wool [040; ≥16; <1000°C] 367,5 90 0,24 adequate 49 (4) 70 (-10,-19) 64,19 221,2

Last update 02.08.2023/hfa.eco2soft