intermediate floor timber frame construction, directly, dry, without filling
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 25,0 | dry screed | 0,210 | 8 | 900 | 1,050 | A1 |
B | 40,0 | 0,040 | 1 | 180 | 1,030 | A1 | |
C | 15,0 | OSB | 0,130 | 200 | 600 | 1,700 | D |
D | 220,0 | construction timber (80/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
E | - variable insulation material | ||||||
F | 12,0 | OSB | 0,130 | 200 | 600 | 1,700 | D |
G | 12,5 | gypsum plaster board type DF | 0,250 | 10 | 800 | 1,050 | A2 |
Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Ln,w(Cl) [dB] | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] |
Last update 06.08.2018/hfa.sp