Fire performance REI 60/K₂60
REI60: maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m² (without floor construction; with ceiling beam 80/200)
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: REI60 K260  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 70 dB (-1; -6)
Ln,w (Cl) 41 dB (1)
Rating by Müller-BBM  
Mass per unit area m 232,5 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 50,0 cement screed or anhydrite screed 1,330 50-100 2000 1,080 A1
B plastic separation layer 0,200 100000 1400 1,400 E
C 30,0 impact sound absorbing subflooring MW-T [s'=10 MN/m³] 0,035 1 68 1,030 A1
D 40,0 fill loose 0,700 1 1800 1,000 A1
E trickling protection E
F 18,0 OSB 0,130 200 600 1,700 D
G 220,0 construction timber (80/..; e=625) 0,120 50 450 1,600 D
H 100,0 mineral wool [040; 30; ≥1000°C] 0,040 1 30 1,030 A1
I spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
J 27,0 resilient channel placed between cladding with spacing
K 36,0 gypsum plaster board type DF (2x...) or 0,250 10 800 1,050 A2
K 36,0 gypsum fibre board (2x...) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 28,0 kg
Share of renewable materials of total weight 11,78 %
Global warming potential (GWP-T) -0,653 kgCO2Äqv.
Energy use of Primary Energy 718,8 MJ
Share of renewable Primary Energy 15,5 %
∑ΔOI3 44,2
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 44,167 -44,820 -0,653 111,066 455,553 566,618 607,715 20,654 628,368 0,175 0,078 2.9847692E-6 0,040

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 32,4 kg
Biogenic carbon 48,1 kgCO2Äqv.
Energy use of Primary Energy 952,9 MJ
Share of renewable Primary Energy 26,1 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -21,609 0,146 0,024 7.93E-7 0,028 244,230 708,240 953,900 651,140 65,900 717,170
C1 - C4 70,354 0,018 0,004 1.06E-7 0,002 3,230 -697,180 -692,810 37,130 -23,150 29,570
A1 - C4 50,782 0,171 0,030 9.21E-7 0,029 248,620 11,580 263,250 704,290 42,900 771,060

Last update 02.08.2023/hfa.eco2soft