intermediate floor timber frame construction, suspended, dry, without filling
Fire performance | REI | 60 |
---|---|---|
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²
Classified by HFA
|
||
Thermal performance | U | 0,27 W/(m2K) |
Diffusion | adequate | |
Acoustic performance | Rw (C;Ctr) | 61 dB (-5; -12) |
Ln,w (Cl) | 60 dB (0) | |
EPS-F with a dynamic stiffness of s' ≤ 40MN/m³.
|
||
Mass per unit area | m | 70,8 kg/m2 |
Calculation based on gypsum plaster board type DF GF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 25,0 | dry screed | 0,210 | 8 | 900 | 1,050 | A1 |
B | 30,0 | Polystyrene EPS-W [0,041] | 0,041 | 20-50 | 15 | 1,450 | E |
C | 18,0 | OSB | 0,130 | 200 | 600 | 1,700 | D |
D | 220,0 | construction timber (80/..; e=625) (80/..; e=*) | 0,120 | 50 | 450 | 1,600 | D |
E | 100,0 | mineral wool [040; ≥16; <1000°C] | 0,040 | 1 | 16 | 1,030 | A1 |
F | 24,0 | spruce wood cladding with spacing of cladding boards(24/100); a=400 | 0,120 | 50 | 450 | 1,600 | D |
G | 27,0 | resilient channel (placed between open formwork) | |||||
H | 25,0 | gypsum plaster board type DF (2x12,5 mm) or | 0,250 | 10 | 800 | 1,050 | A2 |
H | 25,0 | gypsum fibre board (2x12,5 mm) | 0,320 | 21 | 1000 | 1,100 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 25,151 | -40,432 | -15,281 | 89,607 | 406,419 | 496,025 | 421,546 | 33,032 | 454,577 | 0,104 | 0,044 | 2.3086261E-6 | 0,023 |