Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A Rigips Riduro 2x... mm 0,250 4-10 1000 1,050 A2
B 120,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
C - variable insulation material
D - variable building material
E 50,0 RigiProfil >50mm; resilient channel
F - variable insulation material
G - variable building material

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
iwrxxi02b-00 A
C
D
F
G
25,0
120,0
12,5
50,0
12,5
Rigips Riduro
ISOVER Ultimate
Rigips Riduro
mineral wool [040; 11; <1000°C]
Rigips Riduro
220,0 60 57 25,70 60,5
iwrxxi02b-01 A
C
D
F
G
25,0
120,0
25,0
50,0
12,5
Rigips Riduro
ISOVER Multi-Kombi Holzrahmenfilz
Rigips Riduro 2x..
mineral wool [040; 50; ≥1000°C]
Rigips Riduro
232,5 90 57 28,15 74,6
iwrxxi02b-02 A
C
D
F
G
30,0
120,0
30,0
50,0
25,0
Rigips Riduro
ISOVER Ultimate
Rigips Riduro 2x..
mineral wool [040; 11; <1000°C]
Rigips Duo Tech
255,0 90 63 32,30 93,0

Source: Saint-Gobain Austria GmbH

Last update 02.08.2023/nu.ge