internal wall timber frame construction, without dry lining, Gipsplatte
Construction layer B: combination with sill: STEICO GLVL R 60/120
The fire resistance is only valid when wall is used as partition with only one side exposed to fire.
| Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
|---|---|---|---|---|---|---|---|
| λ | μ min – max | ρ | c | ||||
| A | 25,0 | gypsum fibre board 2x12,5mm | 0,320 | 21 | 1000 | 1,100 | A2 |
| B | 120,0 | STEICO LVL R (45/...; e=625) | 0,130 | 70-200 | 480 | 2,100 | D |
| C | - variable insulation material | ||||||
| D | 25,0 | gypsum fibre board 2x12,5mm | 0,320 | 21 | 1000 | 1,100 | A2 |
| Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] | ||
Source: Steico SE
Last update 02.08.2023/nu.ge