Regional validity

Scope

timber frame construction
Cross-section of standard configuration

Note

Construction layer B: combination with sill: STEICO GLVL R 60/120

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 25,0 gypsum fibre board 2x12,5mm 0,320 21 1000 1,100 A2
B 120,0 STEICO LVL R (45/...; e=625) 0,130 70-200 480 2,100 D
C - variable insulation material
D 25,0 gypsum fibre board 2x12,5mm 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
iwrxxo14b-00 C 100,0 STEICOflex [039; 50] 170,0 60 adequate 32,33 58,8
iwrxxo14b-01 C 120,0 STEICOfloc [039; 50] 170,0 60 adequate 30,63 59,2
iwrxxo14b-02 C 120,0 STEICOzell [039; 40] 170,0 60 adequate 30,25 58,6
iwrxxo14b-03 C 100,0 mineral wool [038; ≥33; ≥1000°C] 170,0 60 adequate 36,47 57,2

Source: Steico SE

Last update 02.08.2023/hfa.eco2soft