Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
internal wall timber frame construction, without dry lining, gypsum plasterboard
| Fire performance | REI | 45 |
|---|---|---|
|
maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m
Classified by HFA
|
||
| Thermal performance | U | |
| Diffusion | ||
|
Calculated by HFA
|
||
| Acoustic performance | Rw (C;Ctr) | |
| Ln,w (Cl) | ||
| Mass per unit area | m | 37,7 kg/m2 |
|
Calculation based on gypsum plaster board type DF GF
|
||
data sheet internal wall
iwrxxo03a-06 (pdf, 250 KB)
The fire resistance is only valid when wall is used as partition with only one side exposed to fire.
| Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
|---|---|---|---|---|---|---|---|
| λ | μ min – max | ρ | c | ||||
| A | 15,0 | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 |
| A | 15,0 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
| B | 100,0 | construction timber (60/100 or 60/160; e=*) | 0,120 | 50 | 450 | 1,600 | D |
| C | 100,0 | mineral wool [040; ≥16; <1000°C] | 0,040 | 1 | 16 | 1,030 | A1 |
| D | 15,0 | gypsum fibre board or | 0,320 | 21 | 1000 | 1,100 | A2 |
| D | 15,0 | gypsum plaster board type DF | 0,250 | 10 | 800 | 1,050 | A2 |
| Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
| A1 - A3 | 10,734 | -12,522 | -1,789 | 30,066 | 122,835 | 152,901 | 187,504 | 0,000 | 187,504 | 0,045 | 0,021 | 1.1836339E-6 | 0,008 |
Last update 02.08.2023/nu.ge