Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A concrete roof tile or tiled roof 2100 A1
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C 50,0 spruce wood counter battens (minimum height 50 mm) 0,120 50 450 1,600 D
D 22,0 softboard [045; 250] - rigid underlay 0,045 5 250 2,100 E
E construction timber (80/..; e=800) 0,120 50 450 1,600 D
F - variable insulation material
G 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
H 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
I 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
I 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
sdrhzi04b-00 E
F
200,0
200,0
construction timber
mineral wool [040; ≥16; <1000°C]
366,0 60 0,19 adequate 54 (-2,-8) 31,36 51,1
sdrhzi04b-01 E
F
220,0
220,0
construction timber
mineral wool [040; ≥16; <1000°C]
386,0 60 0,18 adequate 54 (-1,-7) 32,60 52,4
sdrhzi04b-02 E
F
240,0
240,0
construction timber
mineral wool [040; ≥16; <1000°C]
406,0 60 0,17 adequate 55 (-1,-7) 33,83 53,7
sdrhzi04b-03 E
F
200,0
200,0
construction timber
mineral wool [035; 50; <1000°C]
366,0 60 0,18 adequate 55 (-2,-8) 53,97 57,3
sdrhzi04b-04 E
F
200,0
200,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
366,0 60 0,19 adequate 54 (-1,-7) 37,20 54,2
sdrhzi04b-05 E
F
200,0
200,0
construction timber
cellulose fibre [040; E]
366,0 60 0,19 adequate 55 (-2,-8) 24,48 58,2
sdrhzi04b-06 E
F
200,0
200,0
construction timber
sheep wool [0,041; R=26]
366,0 60 0,21 adequate 54 (-3,-9) 25,30 51,1

Last update 02.08.2023/hfa.eco2soft