Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A concrete roof tile or tiled roof 2100 A1
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C 50,0 spruce wood counter battens (minimum height 50 mm) 0,120 50 450 1,600 D
D sarking membrane sd ≤ 0,3m 1000 E
E 24,0 planking spruce wood closed cladding without spacing of cladding boards 0,120 50 450 1,600 D
F construction timber (80/..; e=800) 0,120 50 450 1,600 D
G - variable insulation material
H 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
I spruce wood cross battens (50/80;a=400) 0,120 50 450 1,600 D
J - variable building material
K 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
K 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
sdrhzi06a-00 F
G
I
J
200,0
200,0
50,0
50,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
381,5 30 0,18 adequate 52 (-3,-9) 28,84 50,5
sdrhzi06a-01 F
G
I
J
200,0
200,0
50,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
air layer
381,5 J=without insulation 30 0,20 adequate 50 (-4,-10) 26,01 50,0
sdrhzi06a-02 F
G
I
J
220,0
220,0
50,0
50,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
401,5 30 0,16 adequate 52 (-2,-8) 30,07 51,8
sdrhzi06a-03 F
G
I
J
240,0
240,0
50,0
50,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
421,5 30 0,15 adequate 53 (-2,-8) 31,30 53,1
sdrhzi06a-04 F
G
I
J
200,0
200,0
50,0
50,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
381,5 30 0,16 adequate 53 (-3,-9) 56,46 58,0
sdrhzi06a-05 F
G
I
J
200,0
200,0
50,0
50,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
381,5 30 0,18 adequate 52 (-2,-8) 35,97 54,3
sdrhzi06a-06 F
G
I
J
200,0
200,0
50,0
50,0
construction timber
cellulose fibre [0,040; R=55]
spruce wood
cellulose fibre [0,040; R=55]
381,5 30 0,18 adequate 53 (-3,-9) 20,42 59,1
sdrhzi06a-07 F
G
I
J
200,0
200,0
50,0
50,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
381,5 30 0,19 adequate 52 (-4,-10) 21,43 50,5

Last update 02.08.2023/hfa.eco2soft