Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
pitched roof timber frame construction, ventilated, without dry lining, directly
Fire performance | REI | 30 |
---|---|---|
maximum span = 5 m; maximum load Ed,fi = 4,5 kN/m²
Classified by HFA
|
||
Thermal performance | U | 0,15 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 49 dB (-3; -10) |
Ln,w (Cl) | ||
Rating by TGM
|
||
Mass per unit area | m | 86,3 kg/m2 |
data sheet pitched roof
sdrhzo03a-02 (pdf, 250 KB)
The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | concrete roof tile or tiled roof | 2100 | A1 | ||||
B | 30,0 | spruce wood battens (30/50) | 0,120 | 50 | 450 | 1,600 | D |
C | 50,0 | spruce wood counter battens (minimum height 50 mm) | 0,120 | 50 | 450 | 1,600 | D |
D | sarking membrane sd ≤ 0,3m | 1000 | E | ||||
E | 22,0 | planking spruce wood full formwork | 0,120 | 50 | 450 | 1,600 | D |
F | 280,0 | construction timber (80/..; e=800) | 0,120 | 50 | 450 | 1,600 | D |
G | 280,0 | mineral wool [038; ≥33; ≥1000°C] | 0,038 | 1 | 33 | 1,030 | A1 |
H | vapour barrier sd≥ 11m | 1000 | |||||
I | 19,0 | planking profile C | 0,120 | 50 | 450 | 1,600 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 34,917 | -62,085 | -27,167 | 117,318 | 648,159 | 765,478 | 436,396 | 10,862 | 447,258 | 0,182 | 0,061 | 2.2280332E-6 | 0,072 |
Last update 02.08.2023/hfa.eco2soft