Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 60
maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m  
Classified by MA39  
Thermal performance U 0,25 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 60 dB (-1; -6)
Ln,w (Cl)
Rating by TGM  
Mass per unit area m 82,4 kg/m2
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 15,0 plaster 0,700 10 1300 1,000 A1
B 50,0 Heraklith BM 0,090 2-5 370 2,000 B
C construction timber (60/100; e=625) 0,120 50 450 1,600 D
D 120,0 Heralan KP 0,040 1 28 1,030 A1
E 50,0 Heraklith BM 0,090 2-5 370 2,000 B
F 15,0 plaster 0,700 10 1300 1,000 A1

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 31,6 kg
Share of renewable materials of total weight 38,52 %
Global warming potential (GWP-T) -0,607 kgCO2Äqv.
Energy use of Primary Energy 365,6 MJ
Share of renewable Primary Energy 14,1 %
∑ΔOI3 23,1
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 30,234 -30,841 -0,607 51,449 286,564 338,013 314,177 0,000 314,177 0,096 0,031 1.7568464E-6 0,025

Source: Knauf Insulation GmbH

Last update 02.08.2023/hfa.eco2soft