Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
compartment wall timber frame construction, without dry lining, single-layer, other surface
Fire performance | REI | 60 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m
Classified by MA39
|
||
Thermal performance | U | 0,25 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 60 dB (-1; -6) |
Ln,w (Cl) | ||
Rating by TGM
|
||
Mass per unit area | m | 82,4 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 15,0 | plaster | 0,700 | 10 | 1300 | 1,000 | A1 |
B | 50,0 | Heraklith BM | 0,090 | 2-5 | 370 | 2,000 | B |
C | construction timber (60/100; e=625) | 0,120 | 50 | 450 | 1,600 | D | |
D | 120,0 | Heralan KP | 0,040 | 1 | 28 | 1,030 | A1 |
E | 50,0 | Heraklith BM | 0,090 | 2-5 | 370 | 2,000 | B |
F | 15,0 | plaster | 0,700 | 10 | 1300 | 1,000 | A1 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 30,234 | -30,841 | -0,607 | 51,449 | 286,564 | 338,013 | 314,177 | 0,000 | 314,177 | 0,096 | 0,031 | 1.7568464E-6 | 0,025 |
Source: Knauf Insulation GmbH
Last update 02.08.2023/hfa.eco2soft