Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 65,0 spruce wood cross battens of battens offset 0,120 50 450 1,600 D
C 50,0 wood wool composite boards 0,090 2-5 370 2,000 B
D 16,0 particleboard 0,130 50-100 700 1,700 D
E construction timber (60/..; e=*) 0,120 50 450 1,600 D
F - variable insulation material
G 12,0 particleboard 0,130 50-100 700 1,700 D
H vapour barrier sd≥ 10m 1000
I spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
J - variable building material
K 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
K 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awrohi03a-00 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
325,5 e=625 60 from inside
30 from outside
0,18 adequate 50 (-3,-9) 27,73 69,7
awrohi03a-01 E
F
I
J
120,0
120,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
285,5 e=625 60 from inside
30 from outside
0,21 adequate 49 (-3,-9) 25,09 67,2
awrohi03a-02 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
air layer
325,5 e=625; J=without insulation 60 from inside
30 from outside
0,21 adequate 49 (-3,-9) 22,69 69,2
awrohi03a-03 E
F
I
J
200,0
200,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
365,5 e=625 60 from inside
30 from outside
0,16 adequate 51 (-3,-9) 30,38 72,2
awrohi03a-04 E
F
I
J
240,0
240,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
405,5 e=625 60 from inside
30 from outside
0,14 adequate 52 (-3,-9) 33,02 74,7
awrohi03a-05 E
F
I
J
200,0
200,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
405,5 e=625 60 from inside
30 from outside
0,14 adequate 51 (-3,-9) 32,66 75,2
awrohi03a-06 E
F
I
J
240,0
240,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
445,5 e=625 60 from inside
30 from outside
0,12 adequate 52 (-3,-9) 35,31 77,7
awrohi03a-07 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
325,5 e=625 60 from inside
30 from outside
0,17 adequate 51 (-3,-9) 50,17 75,8
awrohi03a-08 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
325,5 e=625 60 from inside
30 from outside
0,18 adequate 50 (-3,-9) 33,52 72,7
awrohi03a-09 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
cellulose fibre [0,040; R=55]
spruce wood
cellulose fibre [040; E]
325,5 e=625 60 from inside
30 from outside
0,18 adequate 50 (-3,-9) 20,90 76,7
awrohi03a-10 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
325,5 e=625 60 from inside
30 from outside
0,20 adequate 50 (-3,-9) 21,72 69,7
awrohi03a-11 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
325,5 e=400 60 from inside
30 from outside
0,19 adequate 50 (-3,-9) 27,33 74,3

Last update 02.08.2023/hfa.eco2soft