Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall solid wood construction, not ventilated, with dry lining, with rendering
Fire performance |
REI
from inside
REI from outside |
90
90 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/lfm
Classified by HFA
Fire performance Germany
Classification: REI 60 (from inside)/REI90 (from outside); Attention: REI90 (from inside) possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board
Proof: manufacturer-specific
|
||
Thermal performance | U | 0,09 W/(m2K) |
Diffusion | adequate | |
The stated thermal characteristics in the product data sheet are specified for the hard board intermediate web; the flanges are calculated with solid wood.
Calculated by HFA
Calculated by TUM
|
||
Acoustic performance | Rw (C;Ctr) | 63 dB (-2; -7) |
Ln,w (Cl) | ||
Rating by Müller-BBM
|
||
Mass per unit area | m | 108,2 kg/m2 |
Calculation based on gypsum plaster board type DF GKF
|
data sheet external wall
awmopi03a-00 (pdf, 250 KB)
Attention: REI 90 (from inside) in Germany possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 7,0 | plaster | 1,000 | 10-35 | 2000 | 1,130 | A1 |
B | 60,0 | wood-fibre insulation board [045; 190] | 0,045 | 5-7 | 190 | 2,100 | E |
C | 300,0 | Light composite wood-based beams (I-beams) with solid wood flanges (60/45) and hard board intermediate web (≥ 6,7) e=625 | 0,400 | 20-30 | 800 | 1,700 | D |
D | 300,0 | Cellulose fibre [040; 50] | 0,040 | 1 | 50 | 2,000 | E |
E | 100,0 | cross laminated timber ≥ 94,0; at least 3-layers, top layer at least 30 mm | 0,130 | 50 | 500 | 1,600 | D |
F | 70,0 | spruce wood Battens on resilient clips (60/60; e=625) | 0,120 | 50 | 450 | 1,600 | D |
G | 50,0 | Cellulose fibre [040; 50] | 0,040 | 1 | 50 | 2,000 | E |
H | 12,5 | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 |
H | 12,5 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 47,817 | -119,752 | -71,935 | 89,904 | 1163,632 | 1253,536 | 740,049 | 34,421 | 774,470 | 0,234 | 0,100 | 4.1847712E-6 | 0,050 |
Last update 02.08.2023/hfa.eco2soft