Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall timber frame construction, ventilated, with dry lining, with cladding
Fire performance | REI from inside REI from outside |
30 30 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 32 kN/m
Classified by HFA
|
||
Thermal performance | U | 0,20 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 48 dB (-3; -10) |
Ln,w (Cl) | ||
If the battens of the ventilation level are screwed to the structural timber and the battens for the dry lining carried out vertically and screwed to the structural timber the result is Rw≥41dB
Rating by HFA
|
||
Mass per unit area | m | 57,0 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fire | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 24,0 | larch wood external wall cladding | 0,155 | 150 | 600 | 1,600 | D |
B | 30,0 | spruce wood battens offset (30/50; 30/80) - ventilation | 0,120 | 50 | 450 | 1,600 | D |
C | 15,0 | OSB | 0,130 | 200 | 600 | 1,700 | D |
D | 200,0 | construction timber (60/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
E | 200,0 | Cellulose fibre [040; 50] | 0,040 | 1 | 50 | 2,000 | E |
F | vapour barrier sd≥ 4m | 1000 | |||||
G | 40,0 | spruce wood cross battens 40/60mm (a=400) | 0,120 | 50 | 450 | 1,600 | D |
H | 40,0 | air layer | 1 | 1 | 1,008 | ||
I | 16,0 | Kronospan OSB-Firestop | 0,110 | 150-170 | 660 | 1,700 | B |
ΔOI3 | 19,2 |
---|---|
Calculated by HFA
|
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP [kg CO2 Äqv.] |
AP [kg SO2 Äqv.] |
EP [kg PO4 Äqv.] |
ODP [kg R11 Äqv.] |
POCP [kg Ethen Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
A1 - A3 | -61,616 | 0,125 | 0,049 | 1,84e-6 | 0,026 | 90,181 | 873,066 | 963,247 | 353,025 | 29,618 | 382,643 |
Source: KRONOSPAN OSB, spol. s r. o.
Last update 05.08.2020/hfa.plb