Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall timber frame construction, ventilated, without dry lining, with cladding
Fire performance |
REI
from inside
REI from outside |
60
30 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 25,0 kN/m
Classified by HFA
|
||
Thermal performance | U | 0,27 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 45 dB (-2; -8) |
Ln,w (Cl) | ||
Battens for the ventilation space screwed onto the structural timber result in an Rw(C;Ctr)=41(-1;-7) dB
Rating by MA39
|
||
Mass per unit area | m | 34,7 kg/m2 |
Calculation based on gypsum plaster board type DF GF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 24,0 | larch wood external wall cladding | 0,155 | 150 | 600 | 1,600 | D |
B | 30,0 | spruce wood battens offset (30/50; 30/80) - ventilation | 0,120 | 50 | 450 | 1,600 | D |
C | 15,0 | fibreboard (MDF) | 0,140 | 11 | 600 | 1,700 | D |
D | 160,0 | construction timber (60/..; e=*) | 0,120 | 50 | 450 | 1,600 | D |
E | 160,0 | cellulose fibre [040; E] | 0,040 | 1-2 | 55 | 2,000 | E |
F | vapour barrier sd≥ 1m | 1000 | |||||
G | 18,0 | gypsum fibre board or | 0,320 | 21 | 1000 | 1,100 | A2 |
G | 18,0 | gypsum plaster board type DF | 0,250 | 10 | 800 | 1,050 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 16,825 | -57,048 | -40,223 | 103,379 | 590,894 | 694,273 | 269,180 | 22,510 | 291,690 | 0,084 | 0,036 | 1.3527287E-6 | 0,016 |
Last update 02.08.2023/hfa.eco2soft