Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
30
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m  
Classified by HFA  
Thermal performance U 0,12 W/(m2K)
Diffusion adequate
Proof of water vapor diffusion was provided for a structurally permanently secured airtightness of the component in accordance with ÖNORM B 8110-2 (2020) Tab.3 (C=0 m³/(s*PAb)).  
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 51 dB (-6; -13)
Ln,w (Cl)
frequency range 50-3500: C50-3500 -11 dB; Ctr 50-3500 -23 dB  
Rating by MA39/HFA  
Mass per unit area m 54,0 kg/m2
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 4,0 plaster 1,000 10-35 2000 1,130 A1
B 100,0 0,031 20-50 16 1,450 E
C 15,0 OSB 0,130 200 600 1,700 D
D 200,0 construction timber (60/..; e=625) (60/..; e=*) 0,120 50 450 1,600 D
E 200,0 mineral wool [040; 30; ≥1000°C] 0,040 1 30 1,030 A1
F 15,0 OSB 0,130 200 600 1,700 D
G vapour barrier sd≥ 50m 1000
H 30,0 resilient channel a=625 vertical cross battens (a=400) or battens offset)
I 30,0 mineral wool [035; 20; ≥1000°C] or air layer in type 02 0,035 1 20 1,030 A1
J 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
J 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 27,8 kg
Share of renewable materials of total weight 50,82 %
Global warming potential (GWP-T) -11,317 kgCO2Äqv.
Energy use of Primary Energy 617,5 MJ
Share of renewable Primary Energy 16,5 %
∑ΔOI3 42,2
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 34,682 -45,999 -11,317 101,752 474,675 576,427 515,753 90,821 606,574 0,179 0,058 2.1686678E-6 0,063

Last update 02.08.2023/hfa.eco2soft