Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 32 kN/m
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: F60 (from inside/from outside)  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,19 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 51 dB (-2; -8)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 73,4 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board [055; 200] 0,055 5-7 200 2,100 E
C 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
D 160,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E 160,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
F vapour barrier sd≥ 3m 1000
G 15,0 gypsum fibre board 0,320 21 1000 1,100 A2
H 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
H 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 36,3 kg
Share of renewable materials of total weight 48,23 %
Global warming potential (GWP-T) -25,478 kgCO2Äqv.
Energy use of Primary Energy 672,1 MJ
Share of renewable Primary Energy 19,3 %
∑ΔOI3 35,0
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 34,980 -60,457 -25,478 129,664 568,652 698,316 542,394 50,978 593,372 0,146 0,062 2.9826265E-6 0,019

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 40,4 kg
Biogenic carbon 57,2 kgCO2Äqv.
Energy use of Primary Energy 934,6 MJ
Share of renewable Primary Energy 35,5 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -50,440 0,104 0,023 1.27E-6 0,023 329,548 829,211 1159,673 566,871 61,756 628,700
C1 - C4 79,380 0,004 0,001 8.51E-8 0,000 1,505 -819,664 -817,994 24,007 -51,274 -25,060
A1 - C4 30,438 0,112 0,025 1.38E-6 0,023 331,910 10,066 343,259 602,700 10,598 618,950

Last update 02.08.2023/hfa.eco2soft