Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 32 kN/m
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: F60 (from inside/from outside)  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,14 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 53 dB (-2; -8)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 80,1 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board [055; 200] 0,055 5-7 200 2,100 E
C 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
D 240,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E 240,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
F vapour barrier sd≥ 3m 1000
G 15,0 gypsum fibre board 0,320 21 1000 1,100 A2
H 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
H 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 43,3 kg
Share of renewable materials of total weight 52,57 %
Global warming potential (GWP-T) -33,416 kgCO2Äqv.
Energy use of Primary Energy 750,9 MJ
Share of renewable Primary Energy 19,7 %
∑ΔOI3 38,2
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 38,925 -72,342 -33,416 147,600 690,847 838,447 603,287 56,580 659,867 0,163 0,069 3.2920474E-6 0,023

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 48,2 kg
Biogenic carbon 68,5 kgCO2Äqv.
Energy use of Primary Energy 1172,4 MJ
Share of renewable Primary Energy 36,9 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -68,407 0,130 0,029 1.44E-6 0,028 429,516 1077,330 1508,067 697,995 74,587 772,690
C1 - C4 102,939 0,004 0,001 9.51E-8 0,000 1,998 -1067,766 -1065,603 30,199 -64,105 -31,700
A1 - C4 36,030 0,138 0,031 1.55E-6 0,029 432,372 10,082 444,044 740,016 10,598 756,300

Last update 02.08.2023/hfa.eco2soft