Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60/K₂60
60 /K₂60
REI 90 (from inside/from outside); maximum ceiling height = 3 m; maximum load Ed,fi = 19 kN/m  
Classified by HFA  
Fire performance Germany
Classification: manufacturer-specific  
Load Ed,fi according to the German certification document
Thermal performance U 0,13 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 59 dB (-2; -8)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 84,2 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 80,0 MW-PT [040; 150] 0,040 1 150 1,030 A1
C 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
D 240,0 construction timber (60/240; e=625) 0,120 50 450 1,600 D
E 240,0 mineral wool [040; 30; ≥1000°C] 0,040 1 30 1,030 A1
F vapour barrier sd≥ 2m 1000
G 36,0 gypsum plaster board type DF (2x18 mm) or 0,250 10 800 1,050 A2
G 36,0 gypsum fibre board (2x18 mm) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 14,7 kg
Share of renewable materials of total weight 16,71 %
Global warming potential (GWP-T) 27,243 kgCO2Äqv.
Energy use of Primary Energy 796,8 MJ
Share of renewable Primary Energy 13,0 %
∑ΔOI3 65,8
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 50,435 -23,192 27,243 103,420 188,675 292,094 693,425 4,993 698,417 0,285 0,086 3.3709489E-6 0,101

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 11,4 kg
Biogenic carbon 16,6 kgCO2Äqv.
Energy use of Primary Energy 575,1 MJ
Share of renewable Primary Energy 17,9 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 10,704 0,179 0,027 1.1E-6 0,012 100,950 214,709 316,581 431,863 38,031 470,010
C1 - C4 22,778 0,007 0,006 1.16E-7 0,001 0,473 -196,022 -195,385 17,501 -0,119 19,590
A1 - C4 38,918 0,193 0,035 1.25E-6 0,014 102,965 19,463 123,717 472,161 38,116 515,970

Last update 02.08.2023/hfa.eco2soft