Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall timber frame construction, not ventilated, without dry lining, with rendering
Fire performance |
REI
from inside
REI from outside |
60
60 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 23,4 kN/m
Classified by HFA
|
||
Thermal performance | U | 0,16 W/(m2K) |
Diffusion | adequate | |
Calculated by IBO
|
||
Acoustic performance | Rw (C;Ctr) | 44 dB |
Ln,w (Cl) | ||
The acoustic insulation assessment is based on a length-related flow resistance of r≥5 kPa.s/m². If this
value is lower for the insulation material used, the Rw value is reduced by 3dB.
Rating by TGM
|
||
Mass per unit area | m | 83,0 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 7,0 | Plaster „weberpas topdry“ | 0,450 | 10-35 | 1600 | 1,130 | A2 |
B | 140,0 | WF-PT [042; 180] dynamic stiffness s'<15MN/m³. | 0,042 | 3-7 | 180 | 2,100 | E |
C | 15,0 | Rigips Riduro | 0,250 | 4-10 | 1000 | 1,050 | A2 |
D | 160,0 | construction timber (60/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
E | 160,0 | Cellulose fibre [040; 50] | 0,040 | 1 | 50 | 2,000 | E |
F | vapour barrier sd≥ 6m | 1000 | |||||
G | 15,0 | Rigips Riduro | 0,250 | 4-10 | 1000 | 1,050 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 54,782 | -21,192 | 33,590 | 60,085 | 223,860 | 283,945 | 746,373 | 29,600 | 775,973 | 0,323 | 0,093 | 3.4746836E-6 | 0,112 |
Source: Saint-Gobain Austria GmbH
Last update 02.08.2023/nu.ge