Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 60
maximum span = 5 m; maximum load Ed,fi = 4,0 kN/m²  
Classified by HFA  
Thermal performance U 0,19 W/(m2K)
Diffusion
Attention: Due to the application of a moisture-adaptive vapour barrier an object-related proof according to protection against moisture (diffusion) is mandatory. A hygrothermic simulation is necessary (e.g. WUFI)  
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 34 dB
Ln,w (Cl)
Rating by HFA  
Mass per unit area m 54,3 kg/m2
 

data sheet flat roof
fdrobo02a-01 (pdf, 250 KB)

Note

ATTENTION: Regarding protection against moisture an object-related proof in terms of paramter like e.g. climate, shading class etc. is required. Therfore a hygrothermic simulation is necessary (e.g.WUFI), a simple Glaser calculation ist not allowed.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A Plastic roofing membrane E
B 25,0 OSB 0,130 200 600 1,700 D
C 280,0 construction timber (80/280; e=625) 0,120 50 450 1,600 D
D 238,0 mineral wool [040; 33; ≥1000°C] 0,040 1 33 1,030 A1
E moisture-adaptive vapour retarder E
F 32,0 perforated trapezoidal metal sheet E

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 26,8 kg
Share of renewable materials of total weight 62,66 %
Global warming potential (GWP-T) -5,155 kgCO2Äqv.
Energy use of Primary Energy 684,4 MJ
Share of renewable Primary Energy 15,1 %
∑ΔOI3 50,8
Connection joint and screws are disregarded  
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 39,600 -44,756 -5,155 103,368 464,310 567,678 581,000 88,127 669,127 0,220 0,078 3.075835E-6 0,070

Last update 02.08.2023/hfa.eco2soft