Skip to main content
Regional validity

Scope

solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 20,0 Rigidur dry screed 0,200 19 1200 1,100 A1
B - variable insulation material
C 60,0 bonded chippings 0,700 1 1500 1,000 A1
D trickling protection E
E cross laminated timber BBS 125 5 layer 0,130 50 470 1,600 D
F 95,0 Rigips acoustic direct hanger with CD 60/27
G 75,0 mineral wool [040; 18] 0,040 1 18 1,030 A1
H 15,0 gypsum fibre board Rigidur H 0,350 19 1200 1,100 A2
H 15,0 gypsum plaster boards Rigips RF or 0,250 10 900 1,050 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Ln,w(Cl) [dB] Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
gdmtxa01a-02 B
E
10,0
150,0
impact sound absorbing subflooring MW-T [s'= 35MN/m³]
cross laminated timber BBS 125
90 47 (2) 65 (-4,-12) 51,17
gdmtxa01a-03 B
E
10,0
150,0
impact sound absorbing subflooring WF-T
cross laminated timber BBS 125
90 47 (2) 65 (-4,-12) 51,69

Source: Saint-Gobain Austria GmbH

Last update 31.01.2024/hfa.plb