Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 30
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Classified by HFA  
Thermal performance U 0,27 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 66 dB (-1; -6)
Ln,w (Cl) 52 dB (0)
Rating by TGM  
Mass per unit area m 145,8 kg/m2
Calculation based on gypsum plaster board type DF GF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 50,0 anhydrite screed or cement screed 0,700 10 2200 1,300 A1
B plastic separation layer 0,200 100000 1400 1,400 E
C 30,0 impact sound absorbing subflooring MW-T 0,035 1 68 1,030 A1
D 18,0 OSB 0,130 200 600 1,700 D
E 220,0 construction timber (80/..; e=*) 0,120 50 450 1,600 D
F 100,0 cellulose fibre [040; E] 0,040 1-2 55 2,000 E
G 24,0 spruce wood 0,120 50 450 1,600 D
H 27,0 resilient channel (placed between open formwork)
I 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
I 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 29,6 kg
Share of renewable materials of total weight 20,40 %
Global warming potential (GWP-T) -10,007 kgCO2Äqv.
Energy use of Primary Energy 596,6 MJ
Share of renewable Primary Energy 17,8 %
∑ΔOI3 34,3
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 36,450 -46,457 -10,007 105,928 479,358 585,286 490,673 16,832 507,505 0,143 0,069 2.3800141E-6 0,026

Last update 02.08.2023/hfa.eco2soft