Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
intermediate floor timber frame construction, not suspended, dry, with filling
Fire performance | REI | 30 |
---|---|---|
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²
Classified by HFA
|
||
Thermal performance | U | 0,27 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 63 dB (-6; -13) |
Ln,w (Cl) | 58 dB (3) | |
Rating by TGM
|
||
Mass per unit area | m | 135,9 kg/m2 |
Calculation based on gypsum plaster board type DF GF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 25,0 | dry screed | 0,210 | 8 | 900 | 1,050 | A1 |
B | 30,0 | impact sound absorbing subflooring MW-T | 0,035 | 1 | 68 | 1,030 | A1 |
C | 40,0 | fill | 0,700 | 1 | 1800 | 1,000 | A1 |
D | trickling protection | E | |||||
E | 19,0 | particleboard | 0,130 | 50-100 | 700 | 1,700 | D |
F | 220,0 | construction timber (80/..; e=*) | 0,120 | 50 | 450 | 1,600 | D |
G | 100,0 | sheep wool [0,041; R=16] | 0,041 | 1 | 16 | 1,720 | E |
H | 24,0 | spruce wood cladding with spacing of cladding boards(24/100); a=400 | 0,120 | 50 | 450 | 1,600 | D |
I | 12,5 | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 |
I | 12,5 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 25,926 | -49,372 | -23,446 | 66,992 | 505,853 | 572,845 | 440,608 | 33,351 | 473,959 | 0,104 | 0,045 | 2.2779231E-6 | 0,023 |
Last update 02.08.2023/nu.ge