Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 30
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Classified by IBS  
Thermal performance U 0,25 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 51 dB (-3; -10)
Ln,w (Cl) 66 dB (1)
Assessed by TGM  
Mass per unit area m 66,9 kg/m2
Calculation based on gypsum plaster board type DF GF
 
timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 25,0 dry screed 0,210 8 900 1,050 A1
B 30,0 impact sound absorbing subflooring MW-T 0,035 1 68 1,030 A1
C 19,0 particleboard 0,130 50-100 700 1,700 D
D 220,0 construction timber (80/..; e=*) 0,120 50 450 1,600 D
E 100,0 mineral wool [035; 50; <1000°C] 0,035 1 50 1,030 A1
F 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
G 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
G 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

OI3Kon 8,2
Calculated by IBO  

GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
PEI ne
[MJ]
PEI e
[MJ]
EP
[kg PO4 Äqv.]
POCP
[kg C2H4 Äqv.]
-25,7 0,187 717,8 737,3 0,027 0,011

Last update 23.08.2017/hfa.plb