intermediate floor timber frame construction, directly, dry, with filling
Fire performance | REI | 30 |
---|---|---|
with planking 19 mm; maximum span = 5 m; maximum load Ed,fi = 4,5 kN/m² (without floor construction, with ceiling beam 80/220)
Classified by HFA
Fire performance Germany
Classification: F30
Load Ed,fi according to the German certification document
Proof: DIN 4102-4:2016-05, Tabelle 10.12, Zeile 1
|
||
Thermal performance | U | |
Diffusion | adequate | |
Acoustic performance | Rw (C;Ctr) | 57 dB (-6; -13) |
Ln,w (Cl) | 65 dB (3) | |
Rating by Müller-BBM
|
||
Mass per unit area | m | 120,3 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 25,0 | dry screed | 0,210 | 8 | 900 | 1,050 | A1 |
B | 40,0 | impact sound absorbing subflooring [040; s'<40 MN/m³] | 0,040 | 1 | 180 | 1,030 | A1 |
C | 30,0 | fill (m' ca. 45 kg/m²) | 0,700 | 1 | 1800 | 1,000 | A1 |
D | 0,2 | trickling protection | E | ||||
E | 16,0 | OSB | 0,130 | 200 | 600 | 1,700 | D |
F | 220,0 | construction timber (80/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
G | 100,0 | Cellulose fibre [040; 50] | 0,040 | 1 | 50 | 2,000 | E |
H | 16,0 | spruce wood tongeue and groove planking | 0,120 | 50 | 450 | 1,600 | D |
I | 9,5 | gypsum plaster board type A | 0,250 | 4-10 | 680 | 1,050 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 24,292 | -56,033 | -31,741 | 110,924 | 574,390 | 685,314 | 370,540 | 16,350 | 386,890 | 0,126 | 0,045 | 1.9261474E-6 | 0,038 |
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP [kgCO2Äqv.] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
A1 - A3 | -30,634 | 0,106 | 0,017 | 8.75E-7 | 0,020 | 161,926 | 618,418 | 782,290 | 455,916 | 41,699 | 497,751 |
C1 - C4 | 61,770 | 0,012 | 0,006 | 8.18E-8 | 0,001 | 2,927 | -540,317 | -537,391 | 30,759 | -6,888 | 23,871 |
A1 - C4 | 31,880 | 0,119 | 0,024 | 9.63E-7 | 0,021 | 165,168 | 78,361 | 245,474 | 491,237 | 34,853 | 526,226 |