internal wall timber frame construction, without dry lining, other surface
Construction layer B: combination with sill: STEICO GLVL R 60/120
The fire resistance is only valid when wall is used as partition with only one side exposed to fire.
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 25,0 | gypsum plaster board type DF 2x12,5mm | 0,250 | 10 | 800 | 1,050 | A2 |
B | 120,0 | STEICO LVL R (57/...; e=625) | 0,130 | 70-200 | 480 | 2,100 | D |
C | - variable insulation material | ||||||
D | 25,0 | gypsum plaster board type DF 2x12,5mm | 0,250 | 10 | 800 | 1,050 | A2 |
Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] |
Source: Steico SE
Last update 02.08.2023/hfa.eco2soft