Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
internal wall solid wood construction, with dry lining, other surface
Fire performance | REI | 60 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 35 kN/m
Classified by HFA
|
||
Thermal performance | U | |
Diffusion | ||
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 42 dB |
Ln,w (Cl) | ||
Rating by TU-GRAZ
|
||
Mass per unit area | ||
data sheet internal wall
iwmxxo02a-02 (pdf, 250 KB)
The fire resistance is only valid when wall is used as partition with only one side exposed to fire.
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 12,5 | gypsum plaster board type DF | 0,250 | 10 | 800 | 1,050 | A2 |
A | 12,5 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
B | 78,0 | cross laminated timber 3- or 5-ply (e.g. thickness ≥ 78mm; 3-ply at least, surface layer at least 25mm) | 0,130 | 50 | 500 | 1,600 | D |
C | 60,0 | spruce wood battens (60/60; e=625) | 0,120 | 50 | 450 | 1,600 | D |
D | 50,0 | mineral wool [040; 13] | 0,040 | 1 | 13 | 1,030 | A2 |
E | 25,0 | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 |
E | 25,0 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 24,713 | -62,470 | -37,758 | 34,300 | 580,689 | 614,989 | 412,414 | 13,401 | 425,815 | 0,109 | 0,047 | 2.3910704E-6 | 0,032 |
Last update 02.08.2023/hfa.eco2soft