Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
internal wall timber frame construction, without dry lining, wooden surface
Fire performance | REI | 30 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 32 kN/m
Classified by HFA
|
||
Thermal performance | U | |
Diffusion | ||
Acoustic performance | Rw (C;Ctr) | 38 dB (-2; -5) |
Ln,w (Cl) | ||
Rating by TGM
|
||
Mass per unit area | m | 31,2 kg/m2 |
data sheet internal wall
iwrxxo08a-01 (pdf, 250 KB)
The fire resistance is only valid when wall is used as partition with only one side exposed to fire.
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 19,0 | planking profile C | 0,120 | 50 | 450 | 1,600 | |
B | 160,0 | Cellulose fibre [040; 50] | 0,040 | 1 | 50 | 2,000 | E |
C | 160,0 | construction timber (60/160; e=625) | 0,120 | 50 | 450 | 1,600 | D |
D | 19,0 | planking profile C | 0,120 | 50 | 450 | 1,600 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 6,581 | -52,572 | -45,991 | 84,020 | 525,224 | 609,244 | 120,152 | 0,000 | 120,152 | 0,041 | 0,016 | 6.136477E-7 | 0,013 |
Last update 02.08.2023/hfa.eco2soft