Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 30
maximum ceiling height = 3 m; maximum load Ed,fi = 32 kN/m  
Classified by HFA  
Thermal performance U
Diffusion
Acoustic performance Rw (C;Ctr) 37 dB (-2; -6)
Ln,w (Cl)
Rating by TGM  
Mass per unit area m 31,2 kg/m2
 

data sheet internal wall
iwrxxo08a-02 (pdf, 250 KB)

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 19,0 planking profile C 0,120 50 450 1,600
B 160,0 Wood fibre insulation [039; 50] 0,039 1-2 50 2,100 E
C 160,0 construction timber (60/160; e=625) 0,120 50 450 1,600 D
D 19,0 planking profile C 0,120 50 450 1,600

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 32,2 kg
Share of renewable materials of total weight 98,89 %
Global warming potential (GWP-T) -41,899 kgCO2Äqv.
Energy use of Primary Energy 278,1 MJ
Share of renewable Primary Energy 32,9 %
∑ΔOI3 7,2
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 11,688 -53,587 -41,899 91,534 555,573 647,107 186,549 11,204 197,753 0,057 0,026 9.462713E-7 0,016

Last update 02.08.2023/hfa.eco2soft