Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 90
maximum ceiling height = 3 m; maximum load Ed,fi = 27 kN/m  
Classified by HFA  
Thermal performance U
Diffusion
Acoustic performance Rw (C;Ctr) 43 dB
Ln,w (Cl)
The acoustic insulation assessment is based on a length-related flow resistance of r≥5 kPa.s/m². If this value is lower for the insulation material used, the Rw value is reduced by 3dB.  
Rating by TGM  
Mass per unit area m 40,7 kg/m2
 

Datenblatt internal wall
iwrxxo12a-01 (pdf, 250 KB)

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 15,0 Rigips Riduro 0,250 4-10 1000 1,050 A2
B 160,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
C 160,0 ISOVER Ultimate 0,035 1 20 1,030 A1
D 15,0 Rigips Riduro 0,250 4-10 1000 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 20,0
Calculated by IBO  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 2,800 0,073 0,033 1,83e-6 0,011 21,200 143,000 164,200 282,000 0,489 282,489

Source: Saint-Gobain Rigips Austria GesmbH

Last update 06.08.2020/hfa.plb