Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
internal wall timber frame construction, without dry lining, other surface
Fire performance | REI | 90 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 27 kN/m
Classified by HFA
|
||
Thermal performance | U | |
Diffusion | ||
Acoustic performance | Rw (C;Ctr) | 43 dB |
Ln,w (Cl) | ||
The acoustic insulation assessment is based on a length-related flow resistance of r≥5 kPa.s/m². If this
value is lower for the insulation material used, the Rw value is reduced by 3dB.
Rating by TGM
|
||
Mass per unit area | m | 40,7 kg/m2 |
data sheet internal wall
iwrxxo12a-01 (pdf, 250 KB)
The fire resistance is only valid when wall is used as partition with only one side exposed to fire.
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 15,0 | Rigips Riduro | 0,250 | 4-10 | 1000 | 1,050 | A2 |
B | 160,0 | construction timber (60/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
C | 160,0 | ISOVER Ultimate | 0,035 | 1 | 20 | 1,030 | A1 |
D | 15,0 | Rigips Riduro | 0,250 | 4-10 | 1000 | 1,050 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 14,230 | -13,356 | 0,874 | 19,570 | 143,201 | 162,770 | 246,042 | 0,489 | 246,531 | 0,061 | 0,028 | 1.6211764E-6 | 0,010 |
Source: Saint-Gobain Austria GmbH
Last update 02.08.2023/hfa.eco2soft