Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
internal wall timber frame construction, without dry lining, other surface
Fire performance | REI | 60 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 81 kN/m
Classified by HFA
|
||
Thermal performance | U | |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | |
Ln,w (Cl) | ||
Rating by HFA
|
||
Mass per unit area | m | 57,2 kg/m2 |
data sheet internal wall
iwrxxo14b-03 (pdf, 250 KB)
Construction layer B: combination with sill: STEICO GLVL R 60/120
The fire resistance is only valid when wall is used as partition with only one side exposed to fire.
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 25,0 | gypsum fibre board 2x12,5mm | 0,320 | 21 | 1000 | 1,100 | A2 |
B | 120,0 | STEICO LVL R (45/...; e=625) | 0,130 | 70-200 | 480 | 2,100 | D |
C | 100,0 | mineral wool [038; ≥33; ≥1000°C] | 0,038 | 1 | 33 | 1,030 | A1 |
D | 25,0 | gypsum fibre board 2x12,5mm | 0,320 | 21 | 1000 | 1,100 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 31,349 | -25,351 | 5,997 | 242,161 | 88,720 | 330,881 | 447,519 | 9,383 | 456,902 | 0,152 | 0,048 | 2.8427755E-6 | 0,030 |
Source: Steico SE
Last update 02.08.2023/hfa.eco2soft