Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 30
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Classified by HFA  
Thermal performance U 0,20 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 50 dB (-3; -9)
Ln,w (Cl)
with a tiled roof Rw = 48 (-3; -9) dB  
Rating by TGM  
Mass per unit area m 34,6 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet pitched roof
sdrhzi01a-04 (pdf, 250 KB)

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A concrete roof tile or tiled roof 2100 A1
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C 50,0 spruce wood counter battens (minimum height 50 mm) 0,120 50 450 1,600 D
D 22,0 softboard [045; 250] - rigid underlay 0,045 5 250 2,100 E
E 200,0 construction timber (80/..; e=800) 0,120 50 450 1,600 D
F 200,0 mineral wool [038; ≥33; ≥1000°C] 0,038 1 33 1,030 A1
G vapour barrier sd≥ 1m 1000
H 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
I 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
I 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 23,0 kg
Share of renewable materials of total weight 28,02 %
Global warming potential (GWP-T) -5,682 kgCO2Äqv.
Energy use of Primary Energy 472,1 MJ
Share of renewable Primary Energy 14,5 %
∑ΔOI3 32,0
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 31,890 -37,572 -5,682 68,245 386,235 454,479 403,886 12,980 416,866 0,143 0,049 2.2440839E-6 0,051