Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
pitched roof timber frame construction, ventilated, with dry lining, not suspended
Fire performance | REI | 30 |
---|---|---|
maximum span = 5 m; maximum load Ed,fi = 2,62 kN/m² (rafter 60/200 without roofing, counter battens and battens)
Classified by IBS Classified by HFA
|
||
Thermal performance | U | 0,18 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 54 dB (-2; -8) |
Ln,w (Cl) | ||
with a tiled roof Rw = 52 (-2; -8) dB
Assessed by TGM |
||
Mass per unit area | m | 47,3 kg/m2 |
Calculation based on gypsum plaster board type DF GKF
|
Datenblatt pitched roof
sdrhzi04a-03 (pdf, 250 KB)
The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.
Thickness [mm] | Building material | Thermal performance | Reaction to fire | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | concrete roof tile or tiled roof | 2100 | A1 | ||||
B | 30,0 | spruce wood battens (30/50) | 0,120 | 50 | 450 | 1,600 | D |
C | 50,0 | spruce wood counter battens (Austria: minimum height 50 mm), Germany 30 mm | 0,120 | 50 | 450 | 1,600 | D |
D | 22,0 | softboard [045; 250] - rigid underlay | 0,045 | 5 | 250 | 2,100 | E |
E | 200,0 | construction timber (80/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
F | 200,0 | mineral wool [035; 50; <1000°C] | 0,035 | 1 | 50 | 1,030 | A1 |
G | 15,0 | OSB (sealed with airtight tape) | 0,130 | 200 | 600 | 1,700 | D |
H | 24,0 | spruce wood cladding with spacing of cladding boards(24/100); a=400 | 0,120 | 50 | 450 | 1,600 | D |
I | 12,5 | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 |
I | 12,5 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
ΔOI3 | 52,5 |
---|---|
Calculated by HFA |
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase | GWP [kg CO2 Äqv.] | AP [kg SO2 Äqv.] | EP [kg PO4 Äqv.] | ODP [kg R11 Äqv.] | POCP [kg Ethen Äqv.] | PERE [MJ] | PERM [MJ] | PERT [MJ] | PENRE [MJ] | PENRM [MJ] | PENRT [MJ] |
A1 - A3 | -6,375 | 0,218 | 0,095 | 4,42e-6 | 0,012 | 80,476 | 530,731 | 611,206 | 714,082 | 21,104 | 735,186 |
Last update 07.05.2020/hfa.plb