Building physical assessment

Fire performance REI 90
REI45 apply to each individual load-bearing wall; the whole wall: EI90; maximum ceiling height = 3 m; maximum load Ed,fi = 50,0 kN/m
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: F90 (for the whole structure)  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,17 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 61 dB (-2; -9)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 94,9 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 36,0 gypsum plaster board type DF or 0,250 10 800 1,050 A2
A 36,0 gypsum fibre board 0,320 21 1000 1,100 A2
B 100,0 construction timber (60/100; e=*) 0,120 50 450 1,600 D
C 100,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
D 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
D 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
E 30,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
F 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
F 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
G 100,0 construction timber (60/100; e=*) 0,120 50 450 1,600 D
H 100,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
I 36,0 gypsum plaster board type DF or 0,250 10 800 1,050 A2
I 36,0 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 21,6 kg
Share of renewable materials of total weight 22,42 %
Global warming potential (GWP-T) -3,069 kgCO2Äqv.
Energy use of Primary Energy 536,0 MJ
Share of renewable Primary Energy 11,5 %
∑ΔOI3 28,0
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 29,050 -32,119 -3,069 61,729 305,488 367,217 474,296 14,005 488,301 0,092 0,043 3.0336776E-6 0,015

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 21,1 kg
Biogenic carbon 30,4 kgCO2Äqv.
Energy use of Primary Energy 1013,3 MJ
Share of renewable Primary Energy 32,0 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -39,449 0,103 0,024 5.16E-7 0,020 319,151 727,153 1047,071 609,413 44,975 654,480
C1 - C4 70,420 0,007 0,002 1.9E-7 0,001 1,666 -696,069 -694,402 37,831 -37,383 0,450
A1 - C4 33,891 0,122 0,029 7.65E-7 0,022 323,875 32,637 357,281 689,411 8,000 697,500

Last update 02.08.2023/hfa.eco2soft