external wall solid wood construction, ventilated, with dry lining, with cladding
Attention: REI 90 (from inside) in Germany possible with 2x12,5mm GKF/GF
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 24,0 | larch wood external wall cladding | 0,120 | 50 | 450 | 1,600 | D |
B | 30,0 | spruce wood battens (30/50) | 0,120 | 50 | 450 | 1,600 | D |
C | vapour-permeable membrane sd ≤ 0,3m | ||||||
D | 15,0 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
E | 200,0 | construction timber (60/200; e=625) | 0,120 | 50 | 450 | 1,600 | D |
F | - variable insulation material | ||||||
G | cross laminated timber | 0,130 | 50 | 500 | 1,600 | D | |
H | 70,0 | battens (60/60) on resilient clips, e=660 | 0,120 | 50 | 450 | 1,600 | |
I | - variable building material | ||||||
J | 12,5 | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 |
J | 12,5 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] | ||
awmohi02a-04 |
F G I |
200,0
100,0 50,0 |
mineral wool [040; 11; <1000°C] cross laminated timber mineral wool [040; 11; <1000°C] |
451,5 |
90
from inside
60 from outside |
0,15 | adequate | 53 (-2,-8) | 36,23 | 102,6 |
awmohi02a-05 |
F G I |
200,0
100,0 50,0 |
Cellulose fibre [040; 50] cross laminated timber mineral wool [040; 11; <1000°C] |
451,5 |
90
from inside
60 from outside |
0,15 | adequate | 53 (-2,-8) | 34,28 | 109,6 |
awmohi02a-06 |
F G I |
200,0
100,0 50,0 |
Wood fibre insulation [039; 45] cross laminated timber mineral wool [040; 11; <1000°C] |
451,5 |
90
from inside
60 from outside |
0,15 | adequate | 53 (-2,-8) | 35,88 | 107,2 |
Last update 02.08.2023/nu.ge