Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
120
60
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/lfm  
Classified by HFA  
Thermal performance U 0,17 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 54 dB (-4; -11)
Ln,w (Cl)
frequency range 50-3500: C50-3500 -6 dB; Ctr 50-3500 -15 dB  
Rating by HFA  
Mass per unit area m 100,2 kg/m2
 
solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 24,0 larch wood external wall cladding, e.g. clapboard facade 0,155 150 600 1,600 D
B 30,0 spruce wood battens vertical (30/60) ventilation 0,120 50 450 1,600 D
C vapour-permeable membrane sd ≤ 0,3m
D 160,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E 160,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
F 100,0 cross laminated timber 5-ply 0,130 50 500 1,600 D
G 70,0 battens (60/60) vertical on resilient clips, e=625 0,120 50 450 1,600
H 50,0 mineral wool [040; 11; <1000°C] 0,040 1 11 1,030 A1
I 25,0 gypsum plaster board type DF (2x12,5) or 0,250 10 800 1,050 A2
I 25,0 gypsum fibre board (2x12,5) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 34,5
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -128,838 0,197 0,082 3,57e-6 0,013 94,071 1233,925 1327,996 649,525 38,271 687,796

Last update 31.05.2022/hfa.plb