Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
90
60
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/m  
Classified by MA39/HFA  
Fire performance Germany
Classification: REI 90 from inside REI 60 from outside  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,19 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 47 dB (-1; -4)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 104,3 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet external wall
awmoho03a-06 (pdf, 250 KB)

Note

Cross laminated timber:
Variation 00-02 and 04-06: at least 3-layers, top layer at least 30mm; variation 03: d ≥ 85,0; at least 5-layers, top layer at least 17 mm

Only for registered members after logging in.
solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens (30/60) 0,120 50 450 1,600 D
C vapour-permeable membrane sd ≤ 0,3m
D 15,0 gypsum fibre board 0,320 21 1000 1,100 A2
E 200,0 construction timber (60/200; e= 625) 0,120 50 450 1,600 D
F 200,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
G 100,0 cross laminated timber 0,130 50 500 1,600 D
H 12,5 gypsum plaster board type DF / gypsum fibre board 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 78,8 kg
Share of renewable materials of total weight 75,22 %
Global warming potential (GWP-T) -85,687 kgCO2Äqv.
Energy use of Primary Energy 798,0 MJ
Share of renewable Primary Energy 16,7 %
∑ΔOI3 33,9
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 40,706 -126,393 -85,687 133,558 1226,366 1359,924 664,468 37,588 702,057 0,186 0,082 3.6093991E-6 0,054

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 78,2 kg
Biogenic carbon 113,0 kgCO2Äqv.
Energy use of Primary Energy 1229,4 MJ
Share of renewable Primary Energy 40,1 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -119,443 0,139 0,030 2.98E-6 0,030 489,980 1630,870 2118,940 692,420 67,830 759,820
C1 - C4 155,896 0,004 0,001 2.15E-7 0,000 1,870 -1620,580 -1618,710 32,430 -32,080 0,350
A1 - C4 37,271 0,146 0,031 3.22E-6 0,030 492,700 10,810 501,610 736,670 35,870 772,110

Last update 02.08.2023/nu.ge