Building physical assessment

Fire performance REI from inside
REI from outside
60
30
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: F60 (from inside/from outside)  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,16 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 47 dB (-2; -8)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 62,1 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet external wall
awrhho07a-12 (pdf, 250 KB)

Note

According to OIB-RL 2 (Austria) is for ventilated and insulated facades (from building class 2) an insulation material with minimum Euroclass D required.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens - ventilation 0,120 50 450 1,600 D
C 30,0 spruce wood cross battens 0,120 50 450 1,600 D
D wind barrier 1000
E 60,0 wood-fibre insulation board [045; 140] 0,045 2-5 140 2,100 E
F 200,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
G 200,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
H 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
I 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
I 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 48,9 kg
Share of renewable materials of total weight 81,31 %
Global warming potential (GWP-T) -54,026 kgCO2Äqv.
Energy use of Primary Energy 568,0 MJ
Share of renewable Primary Energy 24,0 %
∑ΔOI3 22,6
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 27,342 -81,369 -54,026 136,205 836,456 972,661 431,794 43,333 475,127 0,118 0,054 2.25126E-6 0,025

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 56,2 kg
Biogenic carbon 82,1 kgCO2Äqv.
Energy use of Primary Energy 1064,7 MJ
Share of renewable Primary Energy 39,0 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -82,539 0,120 0,025 7.38E-7 0,032 412,652 1173,722 1586,278 618,052 76,472 694,620
C1 - C4 111,568 0,002 0,000 8.06E-8 0,000 2,159 -1168,611 -1166,453 26,217 -49,010 -22,790
A1 - C4 29,392 0,123 0,026 8.26E-7 0,032 415,190 5,370 420,463 649,498 27,514 677,100