Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall timber frame construction, not ventilated, with dry lining, with rendering
Fire performance | REI from inside | 60 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m
Classified by HFA
|
||
Thermal performance | U | 0,27 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 48 dB (-5; -13) |
Ln,w (Cl) | ||
Rating by TGM
|
||
Mass per unit area | m | 79,0 kg/m2 |
Calculation based on gypsum plaster board type DF GKF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 10,0 | plaster | 1,000 | 10-35 | 2000 | 1,130 | A1 |
B | 25,0 | Heraklith BM | 0,090 | 2-5 | 370 | 2,000 | B |
C | 16,0 | particleboard P5 | 0,130 | 50-100 | 700 | 1,700 | D |
D | 120,0 | construction timber (60/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
E | 120,0 | Heralan KP | 0,040 | 1 | 28 | 1,030 | A1 |
F | vapour barrier sd≥ 9m | 1000 | |||||
G | 50,0 | Heraklith BM | 0,090 | 2-5 | 370 | 2,000 | B |
H | 15,0 | gypsum plaster board type DF | 0,250 | 10 | 800 | 1,050 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 33,590 | -42,614 | -9,024 | 47,841 | 413,063 | 460,903 | 452,949 | 29,823 | 482,772 | 0,131 | 0,046 | 2.3117543E-6 | 0,033 |
Source: Knauf Insulation GmbH
Last update 02.08.2023/nu.ge