Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside 60
maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m  
Classified by HFA  
Thermal performance U 0,19 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 52 dB (-3; -12)
Ln,w (Cl)
Rating by TGM  
Mass per unit area m 85,3 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 10,0 plaster 1,000 10-35 2000 1,130 A1
B 25,0 Heraklith BM 0,090 2-5 370 2,000 B
C 16,0 particleboard P5 0,130 50-100 700 1,700 D
D 200,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E 200,0 Heralan KP 0,040 1 28 1,030 A1
F vapour barrier sd≥ 9m 1000
G 50,0 Heraklith BM 0,090 2-5 370 2,000 B
H 15,0 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 39,0 kg
Share of renewable materials of total weight 47,76 %
Global warming potential (GWP-T) -10,506 kgCO2Äqv.
Energy use of Primary Energy 573,1 MJ
Share of renewable Primary Energy 10,6 %
∑ΔOI3 37,8
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 38,134 -48,640 -10,506 60,793 475,954 536,747 512,344 29,823 542,167 0,161 0,055 2.5300398E-6 0,046

Source: Knauf Insulation GmbH

Last update 02.08.2023/hfa.eco2soft