Register of building materials used for this application, cross-section
(from top to bottom)
|
Thickness [mm] |
Building material |
Thermal performance |
Reaction to fireklasse EN |
λ |
μ min – max |
ρ |
c |
A |
50,0
|
cement screed
or anhydrite screed
|
1,330
|
50-100
|
2000
|
1,080
|
A1
|
B |
|
plastic separation layer
|
0,200
|
100000
|
1400
|
1,400
|
E
|
C |
|
- variable building material
|
|
|
|
|
|
D |
40,0
|
fill
|
0,700
|
1
|
1800
|
1,000
|
A1
|
E |
|
trickling protection
|
|
|
|
|
E
|
F |
19,0
|
particleboard
|
0,130
|
50-100
|
700
|
1,700
|
D
|
G |
|
construction timber
(80/..; e=*)
|
0,120
|
50
|
450
|
1,600
|
D
|
H |
|
- variable insulation material
|
|
|
|
|
|
I |
24,0
|
spruce wood
cladding with spacing of cladding boards(24/100); a=400
|
0,120
|
50
|
450
|
1,600
|
D
|
J |
27,0
|
resilient channel
placed between cladding with spacing
|
|
|
|
|
|
K |
12,5
|
gypsum plaster board type DF
or
|
0,250
|
10
|
800
|
1,050
|
A2
|
K |
12,5
|
gypsum fibre board
|
0,320
|
21
|
1000
|
1,100
|
A2
|
Variations of building components
|
Thickness of layer |
Note |
Fire performance |
Thermal performance |
Acoustic performance |
Eco Sustainability |
Mass |
|
Thickness [mm] |
Building material |
Σ |
REI |
U [W/(m²K)] |
Diffusion |
Ln,w(Cl) [dB] |
Rw (C,Ctr) [dB] |
ΔOI3 |
m [kg/m²] |
gdrnxa08a-00
|
C
G
H
|
30,0
220,0
100,0
|
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
mineral wool [040; ≥16; <1000°C]
|
398,5
|
e=625;
|
30
|
0,26
|
adequate
|
41
(1)
|
70
(-1,-5)
|
41,10
|
216,0
|
gdrnxa08a-01
|
C
G
H
|
30,0
200,0
100,0
|
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
mineral wool [040; ≥16; <1000°C]
|
378,5
|
e=625;
|
30
|
0,26
|
adequate
|
41
(2)
|
70
(-1,-6)
|
41,03
|
214,7
|
gdrnxa08a-02
|
C
G
H
|
30,0
240,0
100,0
|
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
mineral wool [040; ≥16; <1000°C]
|
418,5
|
e=625;
|
30
|
0,26
|
adequate
|
40
(2)
|
71
(-1,-2)
|
41,16
|
217,3
|
gdrnxa08a-03
|
C
G
H
|
30,0
220,0
100,0
|
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
mineral wool [035; 50; <1000°C]
|
398,5
|
e=625;
|
30
|
0,25
|
adequate
|
41
(1)
|
70
(-1,-5)
|
52,05
|
219,0
|
gdrnxa08a-04
|
C
G
H
|
30,0
220,0
200,0
|
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
mineral wool [038; ≥33; ≥1000°C]
|
398,5
|
e=625;
|
60
|
0,26
|
adequate
|
41
(1)
|
70
(-1,-5)
|
43,92
|
217,5
|
gdrnxa08a-05
|
C
G
H
|
30,0
220,0
100,0
|
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
cellulose fibre [040; E]
|
398,5
|
e=625;
|
30
|
0,26
|
adequate
|
41
(1)
|
70
(-1,-6)
|
37,45
|
219,4
|
gdrnxa08a-06
|
C
G
H
|
30,0
220,0
100,0
|
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
sheep wool [0,041; R=16]
|
398,5
|
e=625;
|
30
|
0,28
|
adequate
|
41
(1)
|
70
(-2,-7)
|
36,87
|
216,0
|
gdrnxa08a-07
|
C
G
H
|
30,0
220,0
100,0
|
impact sound absorbing subflooring EPS-T [s'=11 MN/m³]
construction timber
mineral wool [040; ≥16; <1000°C]
|
398,5
|
e=625;
|
30
|
0,27
|
adequate
|
43
(2)
|
70
(-2,-7)
|
33,65
|
214,3
|
gdrnxa08a-08
|
C
G
H
|
30,0
220,0
100,0
|
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
mineral wool [040; ≥16; <1000°C]
|
398,5
|
e=400;
|
30
|
0,27
|
adequate
|
48
(2)
|
67
(-2,-7)
|
40,97
|
223,8
|
gdrnxa08a-09
|
C
G
H
|
30,0
220,0
100,0
|
Polystyrene EPS-W [s'≥26 MN/m³]
construction timber
mineral wool [040; ≥16; <1000°C]
|
398,5
|
e=625;
|
30
|
0,27
|
adequate
|
50
(2)
|
65
(-3,-8)
|
34,10
|
214,4
|
Last update 02.08.2023/nu.ge