Register of building materials used for this application, cross-section (from top to bottom)
|
Thickness [mm] |
Building material |
Thermal performance |
Reaction to fire |
λ |
μ min – max |
ρ |
c |
A |
25,0 |
dry screed |
0,210 |
8 |
900 |
1,050 |
A1 |
B |
|
- variable building material |
|
|
|
|
|
C |
19,0 |
particleboard |
0,130 |
50-100 |
700 |
1,700 |
D |
D |
|
construction timber (80/..; e=*) |
0,120 |
50 |
450 |
1,600 |
D |
E |
|
- variable insulation material |
|
|
|
|
|
F |
24,0 |
spruce wood cladding with spacing of cladding boards(24/100); a=400 |
0,120 |
50 |
450 |
1,600 |
D |
G |
25,0 |
gypsum plaster board type DF (2x12,5 mm) or |
0,250 |
10 |
800 |
1,050 |
A2 |
G |
25,0 |
gypsum fibre board (2x12,5 mm) |
0,320 |
21 |
1000 |
1,100 |
A2 |
Variations of building components
|
Thickness of layer |
Note |
Fire performance |
Thermal performance |
Acoustic performance |
Eco Sustainability |
Mass |
|
Thickness [mm] |
Building material |
Σ |
REI |
U [W/(m²K)] |
Diffusion |
Ln,w(Cl) |
Rw (C,Ctr) |
ΔOI3 |
m [kg/m²] |
gdrtxn03b-00 |
B D E |
30,0 220,0 100,0 |
impact sound absorbing subflooring MW-T construction timber mineral wool [040; ≥16; <1000°C] |
343,0 |
e=625; |
60 |
0,26 |
adequate |
66 |
51 (-3,-10)
| 34,61 |
73,9 |
gdrtxn03b-01 |
B D E |
30,0 200,0 100,0 |
impact sound absorbing subflooring MW-T construction timber mineral wool [040; ≥16; <1000°C] |
323,0 |
e=625; |
60 |
0,26 |
adequate |
66 |
51 (-3,-10)
| 34,55 |
72,6 |
gdrtxn03b-02 |
B D E |
30,0 240,0 100,0 |
impact sound absorbing subflooring MW-T construction timber mineral wool [040; ≥16; <1000°C] |
363,0 |
e=625; |
60 |
0,26 |
adequate |
65 |
52 (-2,-9)
| 34,68 |
75,2 |
gdrtxn03b-03 |
B D E |
30,0 220,0 100,0 |
impact sound absorbing subflooring MW-T construction timber mineral wool [035; 50; <1000°C] |
343,0 |
e=625; |
60 |
0,25 |
adequate |
66 |
50 (-2,-9)
| 45,76 |
76,9 |
gdrtxn03b-04 |
B D E |
30,0 220,0 100,0 |
impact sound absorbing subflooring MW-T construction timber mineral wool [038; ≥33; ≥1000°C] |
343,0 |
e=625; |
60 |
0,26 |
adequate |
66 |
51 (-3,-10)
| 38,52 |
75,4 |
gdrtxn03b-05 |
B D E |
30,0 220,0 100,0 |
impact sound absorbing subflooring MW-T construction timber cellulose fibre [040; E] |
343,0 |
e=625; |
60 |
0,26 |
adequate |
66 |
51 (-2,-9)
| 30,67 |
77,3 |
gdrtxn03b-06 |
B D E |
30,0 220,0 100,0 |
impact sound absorbing subflooring MW-T construction timber sheep wool [0,041; R=16] |
343,0 |
e=625; |
60 |
0,28 |
adequate |
66 |
50 (-3,-10)
| 27,04 |
73,9 |
gdrtxn03b-07 |
B D E |
30,0 220,0 100,0 |
impact sound absorbing subflooring EPS-T construction timber mineral wool [040; ≥16; <1000°C] |
343,0 |
e=625; |
60 |
0,27 |
adequate |
69 |
50 (-3,-10)
| 27,00 |
72,2 |
gdrtxn03b-08 |
B D E |
30,0 220,0 100,0 |
impact sound absorbing subflooring MW-T construction timber mineral wool [040; ≥16; <1000°C] |
343,0 |
e=400; |
60 |
0,27 |
adequate |
69 |
49 (-3,-10)
| 34,48 |
81,7 |
gdrtxn03b-09 |
B D E |
30,0 220,0 100,0 |
Polystyrene EPS-W [0,041] construction timber mineral wool [040; ≥16; <1000°C] |
343,0 |
e=625; |
60 |
0,27 |
adequate |
71 |
49 (-3,-10)
| 27,45 |
72,3 |
Last update 07.05.2020/hfa.plb