internal wall timber frame construction, without dry lining, other surface
Fire performance | REI | 60 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 50,0 kN/m
Classified by MA39 Classified by HFA
Fire performance Germany
Classification: F30/F60 (depending on the corresponding proof)
Load Ed,fi according to the German certification document
Proof: F30: DIN 4102-4:2016-05, Tabelle 10.5,Zeile 5; F60: DIN 4102-4:2016-05, Tablle 10.5, Zeile 10 (if gypsum plaster board type DF or gypsum fibre board 15 mm inside) or manufacturer-specific
|
||
Thermal performance | U | |
Diffusion | ||
Acoustic performance | Rw (C;Ctr) | 43 dB (-1; -5) |
Ln,w (Cl) | ||
Rating by Müller-BBM
|
||
Mass per unit area | m | 48,8 kg/m2 |
Calculation based on gypsum plaster board type DF GKF
|
data sheet internal wall
iwrxxo01b-04 (pdf, 250 KB)
The fire resistance is only valid when wall is used as partition with only one side exposed to fire.
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 25,0 | gypsum plaster board type DF (2x12,5 mm) or | 0,250 | 10 | 800 | 1,050 | A2 |
A | 25,0 | gypsum fibre board (2x12,5 mm) | 0,320 | 21 | 1000 | 1,100 | A2 |
B | 100,0 | construction timber (60/100 or 60/160; e=*) | 0,120 | 50 | 450 | 1,600 | D |
C | 100,0 | Cellulose fibre [040; 50] | 0,040 | 1 | 50 | 2,000 | E |
D | 25,0 | gypsum plaster board type DF (2x12,5 mm) or | 0,250 | 10 | 800 | 1,050 | A2 |
D | 25,0 | gypsum fibre board (2x12,5 mm) | 0,320 | 21 | 1000 | 1,100 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 12,840 | -13,669 | -0,829 | 27,400 | 129,300 | 156,700 | 203,202 | 0,000 | 203,202 | 0,043 | 0,020 | 1.3863722E-6 | 0,006 |
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP [kgCO2Äqv.] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
A1 - A3 | -8,455 | 0,028 | 0,006 | 2.03E-7 | 0,003 | 46,680 | 177,060 | 224,140 | 160,140 | 4,310 | 164,490 |
C1 - C4 | 18,794 | 0,006 | 0,004 | 1.15E-7 | 0,001 | 0,220 | -81,680 | -81,460 | 14,420 | -0,050 | 14,370 |
A1 - C4 | 11,975 | 0,040 | 0,012 | 3.5E-7 | 0,005 | 48,610 | 96,420 | 145,440 | 198,200 | 4,490 | 202,740 |
Last update 02.08.2023/hfa.eco2soft