Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 90
maximum ceiling height = 3 m; maximum load Ed,fi = 19,0 kN/m  
Classified by MA39  
Thermal performance U
Diffusion
Calculated by HFA  
Acoustic performance Rw (C;Ctr)
Ln,w (Cl)
Mass per unit area m 68,6 kg/m2
Calculation based on gypsum plaster board type DF GF
 

Datenblatt internal wall
iwrxxo06b-04 (pdf, 250 KB)

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
A 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2
B 15,0 OSB 0,130 200 600 1,700 D
C 100,0 construction timber (60/100 or 60/160; e=*) 0,120 50 450 1,600 D
D 100,0 cellulose fibre [0,040; R=55] 0,040 1-2 55 2,000 B
E 15,0 OSB 0,130 200 600 1,700 D
F 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
F 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 18,9
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -24,297 0,082 0,034 2,17e-6 0,006 77,026 449,853 526,879 334,201 28,650 362,851

Last update 07.05.2020/hfa.plb