Scope

Building physical assessment

Fire performance REI 60
maximum ceiling height = 3 m; maximum load Ed,fi = 23,4 kN/m  
Classified by HFA  
Thermal performance U
Diffusion
Acoustic performance Rw (C;Ctr) 39 dB
Ln,w (Cl)
The acoustic insulation assessment is based on a length-related flow resistance of r≥5 kPa.s/m². If this value is lower for the insulation material used, the Rw value is reduced by 3dB.  
Rating by TGM  
Mass per unit area m 36,3 kg/m2
 

data sheet internal wall
iwrxxo12a-04 (pdf, 250 KB)

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 12,5 Rigips Riduro 0,250 4-10 1000 1,050 A2
B 120,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
C 120,0 Cellulose fibre [040; 50] 0,040 1 50 2,000 E
D 12,5 Rigips Riduro 0,250 4-10 1000 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 12,0 kg
Share of renewable materials of total weight 33,01 %
Global warming potential (GWP-T) -6,315 kgCO2Äqv.
Energy use of Primary Energy 161,5 MJ
Share of renewable Primary Energy 10,9 %
∑ΔOI3 8,7
Calculated by IBO  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 9,675 -15,990 -6,315 17,616 169,638 187,255 143,903 0,408 144,311 0,037 0,016 1.0277216E-6 0,006

Source: Saint-Gobain Austria GmbH

Last update 02.08.2023/hfa.eco2soft