Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 90
maximum ceiling height = 3 m; maximum load Ed,fi = 100,6 kN/m  
Classified by HFA  
Thermal performance U
Diffusion adequate
Acoustic performance Rw (C;Ctr)
Ln,w (Cl)
Mass per unit area m 67,4 kg/m2
 

data sheet internal wall
iwrxxo13b-00 (pdf, 250 KB)

Note

Construction layer B: combination with sill: STEICO GLVL R 60/120

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 36,0 gypsum fibre board 2x18mm or 0,320 21 1000 1,100 A2
A 36,0 gypsum plaster board type DF 2x18mm 0,250 10 800 1,050 A2
B 120,0 STEICO LVL R (57/...; e=625) 0,130 70-200 480 2,100 D
C 100,0 STEICOflex [039; 50] 0,039 1-2 50 2,100 E
D 36,0 gypsum fibre board 2x18mm or 0,320 21 1000 1,100 A2
D 36,0 gypsum plaster board type DF 2x18mm 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 12,9 kg
Share of renewable materials of total weight 17,16 %
Global warming potential (GWP-T) 3,300 kgCO2Äqv.
Energy use of Primary Energy 437,3 MJ
Share of renewable Primary Energy 18,1 %
∑ΔOI3 22,0
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 21,661 -18,361 3,300 79,080 163,243 242,324 358,215 16,423 374,638 0,067 0,030 2.3452061E-6 0,010

Source: Steico SE

Last update 02.08.2023/hfa.eco2soft