Building physical assessment

Fire performance REI 60
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Classified by HFA  
Thermal performance U 0,19 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 48 dB (-3; -7)
Ln,w (Cl)
Rating by TGM  
Mass per unit area m 60,0 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet flat roof
fdrhbi02b-05 (pdf, 250 KB)

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A Plastic roofing membrane or E
A sheet metal roofing 7800 A1
B 24,0 spruce wood closed cladding without spacing of cladding boards 0,120 50 450 1,600 D
C 80,0 spruce wood counter battens (ventilation) 0,120 50 450 1,600 D
D sarking membrane sd ≤ 0,3m 1000 E
E 22,0 softboard [045; 250] - rigid underlay 0,045 5 250 2,100 E
F 200,0 construction timber (80/*; e=800) 0,120 50 450 1,600 D
G 200,0 cellulose fibre [040; E] 0,040 1-2 55 2,000 E
H 16,0 particleboard 0,130 50-100 700 1,700 D
I vapour barrier sd≥ 1m 1000
J 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
K 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
K 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 51,1 kg
Share of renewable materials of total weight 66,42 %
Global warming potential (GWP-T) -43,242 kgCO2Äqv.
Energy use of Primary Energy 665,7 MJ
Share of renewable Primary Energy 15,9 %
∑ΔOI3 34,7
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 36,015 -79,257 -43,242 105,995 813,076 919,071 559,712 43,985 603,697 0,164 0,075 2.6329408E-6 0,033

Last update 02.08.2023/nu.ge